Bus Cables |
||||||||||
Bus Cables
Armored Hybrid Profibus DP Cable: (2*0.64mm (22AWG) Cu/F-PE/Al-foil screen/TCWB+ Power 2*1.5mm2
Class5 Cu/XLPE) Assembly /LSZH/ GSWA/LSZH, UV resistance, FR to IEC 60332-3-22 Cat.A
Construction:Part A: Profibus DP
Pair No. X Conductor Size |
1PX22AWG 1/0.64mm |
---|---|
Conductor |
Solid plain copper 1/0.64mm |
Insulation |
Foam PE |
Shielding 1 |
Aluminium foil |
Shielding 2 |
Tinned copper wire braid - 65% coverage |
Sheath |
LSZH |
Part B: Power Cable 0.6/1KV
Conductor |
1.5mmsq flexible copper wire to IEC60228 class5 |
---|---|
Insulation |
XLPE,nominal thickness 0.7mm |
Insulation Color |
Black, White or as per request. |
2 parts assembly with fillers
Amour |
Galvanised steel wire,0.9mm diameter |
---|---|
Outer Sheath |
LSFRZH |
Overall Diameter |
16.9 +/-3mm |
Approx. Weight |
375KG/KM |
Core Color of Profibus |
Red&Green |
Sheath Color |
Black or other color upon request |
Electrical Data:
Characteristic Impedance @ 3-20MHz |
150 0 ± 150 |
|
---|---|---|
Conductor Resistance |
54.5 Ohm/km max. |
|
Test Voltage |
1KV |
|
Operate Voltage |
300V RMS |
|
Mutual capacitance |
29.5 pF/m nominal |
|
Max. Attenuation |
0.2MHz |
2 dB/100m |
4MHz |
2.95dB/100m |
|
16MHz |
4.9dB/100m |
Power Cable
Electrical Resistance: 12.1 ohm/km
Insulation Resistance: 1000M oh.km
Rated voltage: 0.6/1KV
Testing voltage:3500V
Technical Data:
Min. Bending Radius |
6-8 x OD mm |
---|---|
Operating Temp.Range, min. |
-30 °C |
Operating Temp.Range, max. |
+90 °C |
Fire Performance
Reduced Fire Propagation (Vertically-mounted bundled cables test) |
IEC 60332-3-22 Cat.A |
---|---|
Halogen Free |
IEC 60754-1/-2 |
Low Smoke Capacity |
IEC 61034-1 |
Flame Retardance |
IEC 60332-1 |